NIPRESS D–500 Flush or inner ceramic diaphragm, max. 600 bar
(Pressure Transmitters)
- 5 years warranty
- Explosion protection
2 / 3-wire mini compact pressure transmitter, with inner or flush diaphragm ceramic sensor, for absolute and gauge pressure measurement. Output: 4…20 mA or 0…10 V, diaphragm: ceramic flush, measuring range: –1…600 bar
D | 5 |
|---|
D | 5 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Gauge | |||||||||||
Absolute |
D | 5 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
¼" BSP (inner diaphragm version only) | |||||||||||
½" BSP (inner or optional flush diaphragm version) | |||||||||||
¼" NPT (inner diaphragm version only) | |||||||||||
½" NPT (inner diaphragm version only) | |||||||||||
M20x1.5 (inner diaphragm version only) |
D | 5 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
–1…0 bar / 4 bar / inner (only with 1% accuracy) | |||||||||||
0…0.4 bar / 1 bar / inner or optional flush diaphragm | |||||||||||
0…0.6 bar / 2 bar / inner or optional flush diaphragm | |||||||||||
0…1 bar / 2 bar / inner or optional flush diaphragm | |||||||||||
0…1.6 bar / 4 bar / inner or optional flush diaphragm | |||||||||||
0…2.5 bar / 4 bar / inner or optional flush diaphragm | |||||||||||
0…4 bar / 10 bar / inner or optional flush diaphragm | |||||||||||
0…6 bar / 10 bar / inner or optional flush diaphragm | |||||||||||
0…10 bar / 20 bar / inner or optional flush diaphragm | |||||||||||
0…16 bar / 40 bar / inner or optional flush diaphragm | |||||||||||
0…25 bar / 40 bar / inner or optional flush diaphragm | |||||||||||
0…40 bar / 100 bar / inner | |||||||||||
0…60 bar / 100 bar / inner | |||||||||||
0…100 bar / 200 bar / inner | |||||||||||
0…160 bar / 400 bar / inner | |||||||||||
0…250 bar / 400 bar / inner | |||||||||||
0…400 bar / 600 bar / inner | |||||||||||
0…600 bar / 800 bar / inner |
D | 5 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
0.5% | |||||||||||
1% (only with underpressure ranges) |
D | 5 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
4…20 mA, 2-wire | |||||||||||
0…10 V, 3-wire | |||||||||||
4…20 mA, 2-wire / Ex ia G | |||||||||||
4…20 mA, 2-wire, SIL 2 | |||||||||||
4…20 mA, 2-wire, SIL 2 / Ex ia G |
Related
Flush diaphragm design (½" BSP only, max. 25 bar) | |||
PVDF process connection (only with ½" BSP, max. 60 bar, open port) | |||
EPDM seal (p ≤ 160 bar) | |||
FFKM seal | |||
PTFE coating on the sensor (only with 0.5% accuracy, p ≥ 0 bar) | |||
Oxygen application (max. 25 bar, FKM seal) | |||
M12x1 (4-pin) IP67 electrical connection, metal | |||
Integrated cable version (IP68), PVC cable (–5…+70 °C) | |||
PVC cable add-on price per meter | |||
Custom measurement range (based on prior negotiations) | |||
** Only for 2-wire version and ISO 4400 connector. | |||
JBD-TTR-04SA ½" BSP / ½" BSP shock absorber | |||