EasyTREK SC–300 4-wire, max. 60 m
(Ultrasonic Integrated Level Transmitters for Solids)
- 5 years warranty
- Explosion protection
4-wire integrated ultrasonic level transmitters for solids with PP or cast aluminum sensor housing with PVC foam face
S | C | D | 3 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
0.6…15 m (40 kHz) | |||||||||||
0.6…30 m (30 kHz) | |||||||||||
1…60 m (15 kHz) |
S | C | D | 3 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
1" BSP thread | |||||||||||
Joystick aiming device |
S | C | D | 3 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
4…20 mA + HART® + SPST solid-state output | |||||||||||
4…20 mA + HART® + SSR / Ex ma ta IIIC |
Related
Maximum length 30 m; sold by the meter over the standard 5 m | |||
Accessories
UNIMOUNT SAA Aiming Device
Joystick aiming device for adjusting the measuring angle of the level transmitter, with PG9-type cable gland, DN50 PN16 flange mounting design, 1" BSP device connection
S | A | A | 1 | 2 | 0 | Joystick aiming device |
|---|
S | A | A | 1 | 2 | 0 | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
200 mm / ~260 mm | |||||||||||
300 mm / ~360 mm | |||||||||||
400 mm / ~460 mm | |||||||||||
550 mm / ~610 mm |
NIVOSONAR SAA Damping gland
Damping gland for mounting SP devices to thin metal roofs, PP
S | A | A | 1 | 0 | 6 | 0 | Damping gland for mounting SP devices to thin metal roofs, PP |
|---|
NIVOSONAR SFA Flanges
Plastic flanges for ultrasonic level transmitters, Material: Polypropylene (PP)
S | F | A | 3 | Flanges |
|---|
S | F | A | 3 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
DIN flanges, PN16 | |||||||||||
DN80 PN16 | |||||||||||
DN100 PN16 | |||||||||||
DN125 PN16 | |||||||||||
DN150 PN16 | |||||||||||
DN200 PN16 | |||||||||||
DN250 PN16 | |||||||||||
DN300 PN16 | |||||||||||
DN350 PN16 | |||||||||||
FF ANSI flanges, 150 psi | |||||||||||
3" FF 150 psi | |||||||||||
4" FF 150 psi | |||||||||||
5" FF 150 psi | |||||||||||
6" FF 150 psi | |||||||||||
8" FF 150 psi | |||||||||||
12” FF 150 psi | |||||||||||
14” FF 150psi | |||||||||||
JIS flanges, 10K | |||||||||||
80A (as per 10K) | |||||||||||
100A (as per 10K) | |||||||||||
125A (as per 10K) | |||||||||||
150A (as per 10K) | |||||||||||
200A (as per 10K) | |||||||||||
300A (as per 10K) | |||||||||||
350A (as per 10K) | |||||||||||
S | F | A | 3 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
⌀35 mm hole (for units with 1" BSP process connection) | |||||||||||
For units with 2" BSP process connection | |||||||||||
For units with 2" NPT process connection | |||||||||||
For mounting to SAA-102 aiming device | |||||||||||
For units with 1½" BSP process connection | |||||||||||
For units with 1½" NPT process connection |
S | F | A | 3 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Standard hole |
MonoCONT PDF–410
Controlador e display de loop de campo compatível com HART®, canal único, montagem na parede, programa e lê remotamente 1 transmissor com saída de 4...20 mA / HART®.
P | F | 1 | Smart Field Display and Data Logger |
|---|
P | F | 1 | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Display | |||||||||||
Display + Bluetooth® | |||||||||||
Without display + Bluetooth® | |||||||||||
Display + data logging + Bluetooth® |
P | F | 1 | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Painted aluminum | |||||||||||
Fiberglass-reinforced plastic (PBT) | |||||||||||
Stainless steel |
P | F | 1 | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Solid-state relay (SSR) output | |||||||||||
Solid-state relay (SSR) output + RS485 (only in 3- or 4-wire version) | |||||||||||
Solid-state relay (SSR) output + SPDT relay (only in 4-wire version) | |||||||||||
Solid-state relay (SSR) output + SPDT relay + RS485 (only in 4-wire version) |
P | F | 1 | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
4-wire 85…230 V AC | |||||||||||
2-wire loop powered | |||||||||||
3-wire 8…30 V DC | |||||||||||
4-wire 24 V DC | |||||||||||
2-wire loop powered / Ex ia G/D | |||||||||||
3-wire 8…30 V DC / Ex ia G/D | |||||||||||
4-wire 24 V DC / Ex ia G/D | |||||||||||
4-wire 85…230 V AC / Ex d G/tD | |||||||||||
2-wire loop powered / Ex d G/tD | |||||||||||
3-wire 8…30 V DC / Ex d G/tD | |||||||||||
4-wire 24 V DC / Ex d G/tD | |||||||||||
4-wire 85…230 V AC / Ex d ia G | |||||||||||
2-wire loop powered / Ex d ia G | |||||||||||
3-wire 8…30 V DC / Ex d ia G | |||||||||||
4-wire 24 V DC / Ex d ia G |
UNICONT PDF–400
Wall-mountable universally scalable 2-wire passive process value indicators and 3-wire active field loop current display / HART converter units, input: 4…20 mA
P | F | 0 | 1 | Loop Display |
|---|
P | F | 0 | 1 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Without plug-in display | |||||||||||
With plug-in display |
P | F | 0 | 1 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Painted aluminum | |||||||||||
Fiberglass-reinforced plastic (PBT) | |||||||||||
Stainless steel |
P | F | 0 | 1 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
(2-wire, HART® transparent) | |||||||||||
4…20 mA + HART® (3-wire, 4…20 mA -> HART® converter) | |||||||||||
/ Ex ia G (2-wire, HART® transparent) | |||||||||||
4…20 mA + HART® / Ex ia G (3-wire, 4…20 mA -> HART® converter) | |||||||||||
/ Ex d G (2-wire, HART® transparent) | |||||||||||
4…20 mA + HART® / Ex d G (3-wire, 4…20 mA -> HART® converter) | |||||||||||
/ Ex d ia G (2-wire, HART® transparent) | |||||||||||
4…20 mA + HART® / Ex d ia G (3-wire, 4…20 mA -> HART® converter) |
MultiCONT P–200
Wall-mountable universal multichannel process controller unit to remote program and read all NIVELCO transmitters featuring HART® communication, expandable with relay and current output modules
P | 2 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Standard, non expandable | |||||||||||
Expandable (with universal interface module) |
P | 2 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
IP65 Enclosure / LCD | |||||||||||
IP20 Enclosure / Datalogger / LCD | |||||||||||
IP65 Enclosure, transparent cover / LCD | |||||||||||
IP65 Enclosure, transparent cover + Datalogger / LCD | |||||||||||
IP65 Enclosure / OLED | |||||||||||
IP65 Enclosure, transparent cover / OLED | |||||||||||
IP65 Enclosure, transparent cover + Datalogger / OLED |
P | 2 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Single channel for one unit | |||||||||||
2 channels for up to 2 units | |||||||||||
4 channels for up to 4 units | |||||||||||
8 channels for up to 8 units | |||||||||||
15 channels for up to 15 units |
P | 2 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Display | |||||||||||
Display and 1× SPDT Relay | |||||||||||
Display and 2× SPDT Relays | |||||||||||
Display and 3× SPDT relays | |||||||||||
Display and 4× SPDT relays | |||||||||||
Display and 5× SPDT relays | |||||||||||
Display, 1× 4…20 mA current output | |||||||||||
Display, 1× 4…20 mA current output and 1× SPDT relay | |||||||||||
Display, 1× 4…20 mA current output and 2× SPDT relays | |||||||||||
Display, 1× 4…20 mA current output and 3× SPDT relays | |||||||||||
Display, 1× 4…20 mA current output and 4× SPDT relays | |||||||||||
Display, 1× 4…20 mA current output and 5× SPDT relays | |||||||||||
Display and 2× 4…20 mA current output | |||||||||||
Display, 2× 4…20 mA current output and 1× SPDT relay | |||||||||||
Display, 2× 4…20 mA current output and 2× SPDT relays | |||||||||||
Display, 2× 4…20 mA current output and 3× SPDT relays | |||||||||||
Display, 2× 4…20 mA current output and 4× SPDT relays | |||||||||||
Display + RS485 interface | |||||||||||
Display + RS485 interface and 1× SPDT relay | |||||||||||
Display + RS485 interface and 2× SPDT relays | |||||||||||
Display + RS485 interface and 3× SPDT relays | |||||||||||
Display + RS485 interface and 4× SPDT relays | |||||||||||
Display + RS485 interface and 5× SPDT relays | |||||||||||
Display + RS485 interface and 1× 4…20 mA current output | |||||||||||
Display + RS485 interface, 1× 4…20 mA current output and 1× SPDT relay | |||||||||||
Display + RS485 interface, 1× 4…20 mA current output and 2× SPDT relays | |||||||||||
Display + RS485 interface, 1× 4…20 mA current output and 3× SPDT relays | |||||||||||
Display + RS485 interface, 1× 4…20 mA current output and 4× SPDT relays | |||||||||||
Display + RS485 interface, 1× 4…20 mA current output and 5× SPDT relays | |||||||||||
Display + RS485 interface, 2× 4…20 mA current output | |||||||||||
Display + RS485 interface, 2× 4…20 mA current output and 1× SPDT relay | |||||||||||
Display + RS485 interface, 2× 4…20 mA current output and 2× SPDT relays | |||||||||||
Display + RS485 interface, 2× 4…20 mA current output and 3× SPDT relays | |||||||||||
Display + RS485 interface, 2× 4…20 mA current output and 4× SPDT relays |
P | 2 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
85…255 V AC | |||||||||||
11.4…28 V AC and 11.4…40 V DC | |||||||||||
85…255 V AC / [Ex ia G/D] (max. 4 channels) | |||||||||||
11.4…28 V AC and 11.4…40 V DC / [Ex ia G/D] (max. 4 channels) |
UNICOMM SAT–504 HART®-USB/Bluetooth® modem
HART®-USB communication modem for transmitters with HART® output USB 1.1 “B” connector and test clip
S | A | T | 5 | 0 | 4 | HART®-USB/Bluetooth® modem |
|---|
S | A | T | 5 | 0 | 4 | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
HART®-USB modem | |||||||||||
HART®-USB modem + power supply for transmitter | |||||||||||
HART®-USB modem + power supply for transmitter + Bluetooth® | |||||||||||
HART®-USB modem + power supply for transmitter + service port | |||||||||||
HART®-USB modem + power supply for transmitter + service port + Bluetooth® |